Removal of dust from flue gas in magnetically stabilized fluidized bed
O6; A magnetically stabilized fluidized bed (MSFB, φ 500mm x 2100mm) was designed to study dust removal from flue gas. Based on the mechanism of dust removal in a fixed bed, the effects on collection efficiency of magnetic field intensity, ratio of flue gas velocity to minimum fluidization velocity,...
Saved in:
Published in | 中国颗粒学报(英文版) Vol. 6; no. 2; pp. 116 - 119 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, Jiangsu, China%Key Laboratory of Clean Coal Power Generation and Combustion Technology of Ministry of Education,Southeast University, Nanjing 210096, Jiangsu, China
2008
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | O6; A magnetically stabilized fluidized bed (MSFB, φ 500mm x 2100mm) was designed to study dust removal from flue gas. Based on the mechanism of dust removal in a fixed bed, the effects on collection efficiency of magnetic field intensity, ratio of flue gas velocity to minimum fluidization velocity, bed height, and particle average diameter, were investigated. Then feasible methods for MSFB to better remove dust were proposed. Over 95% of dust removal with MSFB can be achieved, when stable fluidization is maintained and when magnetic particles are frequently renewed. |
---|---|
ISSN: | 1672-2515 |