Dose perturbation effects by metal hip prosthesis in gynaecological 192 Ir HDR brachytherapy
The present study was conducted to elucidate the effects of hip prostheses in Ir HDR brachytherapy and determine dose uncertainties introduced by the treatment planning. A gynaecological phantom irradiated using Nucletron Ir microSelectron HDR source was modeled using MCNP5 code. Three hip materials...
Saved in:
Published in | Applied radiation and isotopes Vol. 196; p. 110751 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
England
01.06.2023
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The present study was conducted to elucidate the effects of hip prostheses in
Ir HDR brachytherapy and determine dose uncertainties introduced by the treatment planning. A gynaecological phantom irradiated using Nucletron
Ir microSelectron HDR source was modeled using MCNP5 code. Three hip materials considered in this study were water, bone, and metal prosthesis. According to the obtained results, a dose perturbation was observed within the medium with a higher atomic number, which reduced the dose to the nearby region. |
---|---|