Liver T1 Relaxation Quantification Using a 3-Dimensional Interleaved Look-Locker Acquisition With T2 Preparation Pulse Sequence (3D-QALAS): Comparison With Conventional 2-Dimensional MOLLI

Changes in liver magnetic resonance imaging T1 relaxation times are associated with histologic inflammation and fibrosis. To compare liver T1 measurements obtained using a novel single-breath-hold 3-dimensional (3D) whole-liver T1 estimation method (3D-QALAS) to standard-of-care 2-dimensional (2D) m...

Full description

Saved in:
Bibliographic Details
Published inJournal of computer assisted tomography
Main Authors Gandhi, Deep B, Pednekar, Amol, Wang, Hui, Tkach, Jean A, Dudley, Jonathan A, Manhard, Mary Kate, Trout, Andrew T, Dillman, Jonathan R
Format Journal Article
LanguageEnglish
Published United States 27.12.2022
Online AccessGet more information

Cover

Loading…
More Information
Summary:Changes in liver magnetic resonance imaging T1 relaxation times are associated with histologic inflammation and fibrosis. To compare liver T1 measurements obtained using a novel single-breath-hold 3-dimensional (3D) whole-liver T1 estimation method (3D-QALAS) to standard-of-care 2-dimensional (2D) modified Look-Locker (2D-MOLLI) measurements. With institutional review board approval, research magnetic resonance imaging examinations were performed in 19 participants at 1.5 T. T1 relaxometry of the liver was performed using a novel 3D whole-liver T1 estimation method (3D-QALAS) as well as a 2D modified Look-Locker (2D-MOLLI) method. The 3D method covered the entire liver in a single breath hold, whereas 2D imaging was performed at 4 anatomic levels in 4 consecutive breath holds. T1 measurements from parametric maps were obtained by a single operator, and region-of-interest area-weighted mean T1 values were calculated. Pearson correlation ( r ) was used to assess correlation between T1 estimation methods, and the paired t test and Bland-Altman analysis were used to compare agreement in T1 measurements. In 18 participants (1 participant was excluded from analysis because of respiratory motion artifacts on 3D-QALAS images), 2D-MOLLI and 3D-QALAS mean T1 measurements were strongly correlated ( r = 0.95, [95% CI: 0.87-0.98]; P < 0.0001). 2D-MOLLI T1 values were significantly longer than 3D-QALAS values (647.2 ± 87.3 milliseconds vs. 554.7 ± 75.8 milliseconds; P < 0.0001) with mean bias = 92.5 milliseconds (95% limits of agreement, 36.8, 148.2 milliseconds). Whole-liver T1 measurements obtained using a novel single-breath-hold 3D T1 estimation method correlate with a standard-of-care multiple consecutive-breath-hold 2D single-slice method but demonstrate systematic bias that should be considered or corrected when used in a clinical or research setting.
ISSN:1532-3145