Indoor Test System for Liquid CO 2 Phase Change Shock Wave Pressure with PVDF Sensors

Liquid carbon dioxide phase change fracturing technology (LCPCFT) has been widely used in engineering blasting due to the advantage of no flames, and no toxic and harmful gas. However, few studies have been conducted on the acquisition of shock wave pressure and its loading characteristics, which ar...

Full description

Saved in:
Bibliographic Details
Published inSensors (Basel, Switzerland) Vol. 20; no. 8
Main Authors Huang, Xing, Li, Qiyue, Wei, Xin'ao, Yang, Xiaoxiao, Luo, Dayou, Zeng, Haideng, Wang, Hongwei
Format Journal Article
LanguageEnglish
Published Switzerland 23.04.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Liquid carbon dioxide phase change fracturing technology (LCPCFT) has been widely used in engineering blasting due to the advantage of no flames, and no toxic and harmful gas. However, few studies have been conducted on the acquisition of shock wave pressure and its loading characteristics, which are key parameters in fracturing. Referring to the CO in-situ fracturing technology, an indoor test system for shock wave pressure generated during LCPCFT has been built, with a protected polyvinylidene fluoride (PVDF) piezoelectric sensor. Then three verification experiments with different radial distances between the fracturing tube and test points were carried out on the test system, and in each experiment, four PVDF sensors as four test points were arranged with different axial distance from the detonating point to test the pressure distribution. The experimental results show that when the radial distance between the fracturing tube and test points is not too large (≤345 mm), the pressure generated during LCPCFT is approximately uniformly distributed within the axial length of the fracturing tube, but when it is relatively large (≈895 mm), the results between different test points are in a certain degree of dispersion. And finally, this paper uses the intraclass correlation coefficient (ICC) and coefficient of variation (C ) of peak pressure and impulse to process the test results to evaluate the reliability and stability of the test system. Evaluation results show that the test results are in good consistency. The test system in this paper has good stability and high reliability. The test system provides a useful tool for accurately obtaining the shock wave pressure, which is helpful for further research on LCPCFT.
ISSN:1424-8220