Proposal of a New Specific Cardiopulmonary Exercise Test for Taekwondo Athletes
The objective of this study is to evaluate the cardiorespiratory variables of Taekwondo athletes while performing incremental exercise test on ergometer using a ramp protocol and to propose a specific protocol for assessing these physiological variables during Taekwondo practice. Fourteen athletes p...
Saved in:
Published in | Journal of strength and conditioning research |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
18.12.2015
|
Online Access | Get more information |
Cover
Loading…
Summary: | The objective of this study is to evaluate the cardiorespiratory variables of Taekwondo athletes while performing incremental exercise test on ergometer using a ramp protocol and to propose a specific protocol for assessing these physiological variables during Taekwondo practice. Fourteen athletes participated in two incremental exercise tests: a treadmill exercise test (TREADtest) and a Taekwondo-specific exercise test (TKDtest). The TKDtest consists in one-minute stages of kicks with an incremental load between then. The subjects perform kicks each time a sound signal was heard. Heart rate (HR), oxygen uptake (V[Combining Dot Above]O2), and their reserve correspondents (V[Combining Dot Above]O2R and HRR) were divided into quartiles to verify their kinetics along the tests. Significant difference between two tests was found only for V[Combining Dot Above]O2R (p = 0.03). Regarding the quartiles, significant differences were found for HR in the 1 (p = 0.030) and 2 (p = 0.003). Analyzing the regression curves, significant differences were found for HR for intercept (p = 0.01) and slope (p = 0.05) and HRR for slope (p = 0.02). Analysis showed significant reliability, with intraclass correlation coefficient (ICC), was found for the V[Combining Dot Above]O2PEAK (ICC = 0.855, p = 0.003), V[Combining Dot Above]O2 in ventilatory thresholds 1 (ICC = 0.709, p = 0.03) and 2 (ICC = 0.848, p = 0.003). Bland-Altman analyses reported a mean difference ± the 95% limits of agreement of 2.2 ± 8.4 ml.kg.min to V[Combining Dot Above]O2PEAK. TKDtest is reliable for measurement of cardiorespiratory variables, and the behavior of these variables differs mainly from TREADtest, probably due to the motor task performed. |
---|---|
ISSN: | 1064-8011 1533-4287 |