Fluorescence detection of pituitary neuroendocrine tumour during endoscopic transsphenoidal surgery using bevacizumab-800CW: a non-randomised, non-blinded, single centre feasibility and dose finding trial DEPARTURE trial
Achieving endocrine remission by gross total resection is challenging in pituitary neuroendocrine tumours (PitNETs) with cavernous sinus invasion. This study aims to assess the safety, feasibility, and optimal dose for intraoperative fluorescence imaging as an added instrument to discriminate PitNET...
Saved in:
Published in | European journal of nuclear medicine and molecular imaging |
---|---|
Main Authors | , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
11.10.2024
|
Online Access | Get full text |
Cover
Loading…
Summary: | Achieving endocrine remission by gross total resection is challenging in pituitary neuroendocrine tumours (PitNETs) with cavernous sinus invasion. This study aims to assess the safety, feasibility, and optimal dose for intraoperative fluorescence imaging as an added instrument to discriminate PitNET from surrounding tissue using bevacizumab-800CW, targeting vascular endothelial growth factor A (VEGF-A).PURPOSEAchieving endocrine remission by gross total resection is challenging in pituitary neuroendocrine tumours (PitNETs) with cavernous sinus invasion. This study aims to assess the safety, feasibility, and optimal dose for intraoperative fluorescence imaging as an added instrument to discriminate PitNET from surrounding tissue using bevacizumab-800CW, targeting vascular endothelial growth factor A (VEGF-A).In part I, dose-escalation (0-4∙5-10-25 mg) was performed in 4 groups of 3 patients with PitNETs Knosp grade 3-4. In part II, after interim analysis, the 10 mg and 25 mg groups were expanded to a total of 6 patients. Quantitative fluoroscence molecular endoscopy consisted of wide field fluorescence molecular endoscopy and multi-diameter single fiber reflectance / single fiber fluorescence spectroscopy. Mean fluorescence intensity (MFI) of the fresh surgical specimen was calculated and VEGF-staining was performed.METHODSIn part I, dose-escalation (0-4∙5-10-25 mg) was performed in 4 groups of 3 patients with PitNETs Knosp grade 3-4. In part II, after interim analysis, the 10 mg and 25 mg groups were expanded to a total of 6 patients. Quantitative fluoroscence molecular endoscopy consisted of wide field fluorescence molecular endoscopy and multi-diameter single fiber reflectance / single fiber fluorescence spectroscopy. Mean fluorescence intensity (MFI) of the fresh surgical specimen was calculated and VEGF-staining was performed.Eighteen patients were included. All doses were well tolerated. Three serious adverse events were registered, but none were tracer-related. Part I showed an adequate in-vivo tumour-to-background ratio for both 10 mg (TBR 2∙00 [1∙86, 2∙19]) and 25 mg (TBR 2∙10, [1∙86, 2∙58]). Part II revealed a substantially higher MFI in the 25 mg group. With both 10 mg and 25 mg a statistically significant difference between tumour and surrounding tissue was detected (p < 0∙0001). All surgical specimens had VEGF-A expression.RESULTSEighteen patients were included. All doses were well tolerated. Three serious adverse events were registered, but none were tracer-related. Part I showed an adequate in-vivo tumour-to-background ratio for both 10 mg (TBR 2∙00 [1∙86, 2∙19]) and 25 mg (TBR 2∙10, [1∙86, 2∙58]). Part II revealed a substantially higher MFI in the 25 mg group. With both 10 mg and 25 mg a statistically significant difference between tumour and surrounding tissue was detected (p < 0∙0001). All surgical specimens had VEGF-A expression.This study demonstrates the safety and feasibility of quantitative fluorescence molecular endoscopy during PitNET surgery. Both 10 mg and 25 mg bevacizumab-800CW result in clear differentiation in-vivo, with improved contrast ex-vivo (MFI) in the 25 mg group.CONCLUSIONThis study demonstrates the safety and feasibility of quantitative fluorescence molecular endoscopy during PitNET surgery. Both 10 mg and 25 mg bevacizumab-800CW result in clear differentiation in-vivo, with improved contrast ex-vivo (MFI) in the 25 mg group.NCT04212793 / Study Details| Detection of PitNET Tissue During TSS Using Bevacizumab800CW| ClinicalTrials.gov.TRIAL REGISTRATIONNCT04212793 / Study Details| Detection of PitNET Tissue During TSS Using Bevacizumab800CW| ClinicalTrials.gov. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 content type line 23 ObjectType-Feature-2 |
ISSN: | 1619-7089 1619-7089 |