Anti-Vibration Performance Proof Test for an Optimized Stiffness Distribution of Elasto-Plastic Joint Elements for Boiler Structures
Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deal...
Saved in:
Published in | Nihon Kikai Gakkai ronbunshū. C Vol. 16; no. 10; pp. 2817 - 2821 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | Japanese |
Published |
01.01.2004
|
Online Access | Get full text |
Cover
Loading…
Summary: | Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deals with an anti-vibration performance proof test for an optimized stiffness distribution of elasto-plastic joint elements for boiler structures using a down-scaled boiler structure model on a large shaking table. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 content type line 23 ObjectType-Feature-1 |
ISSN: | 0387-5024 |