Anti-Vibration Performance Proof Test for an Optimized Stiffness Distribution of Elasto-Plastic Joint Elements for Boiler Structures

Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deal...

Full description

Saved in:
Bibliographic Details
Published inNihon Kikai Gakkai ronbunshū. C Vol. 16; no. 10; pp. 2817 - 2821
Main Authors Aida, Kiyoshi, Owa, Yasuyuki, Murayama, Naotomo, Kawamura, Koutaro, Suzuki, Kohei, Fujita, Satoshi, Chiba, Toshio
Format Journal Article
LanguageJapanese
Published 01.01.2004
Online AccessGet full text

Cover

Loading…
More Information
Summary:Seismic ties are the connecting devices installed between a boiler and its supporting structure in thermal power plants. The seismic ties are made of steel and allowed to be used in the elasto-plastic deformation region in order to reduce the seismic response of the boiler structure. This paper deals with an anti-vibration performance proof test for an optimized stiffness distribution of elasto-plastic joint elements for boiler structures using a down-scaled boiler structure model on a large shaking table.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
content type line 23
ObjectType-Feature-1
ISSN:0387-5024