Influence of the Double-Layer Capacity in Periodically Changing Rate Metal Electrodeposition

The departure of the faradaic current from the total imposed periodically changing current has been investigated for both an ideal system (dummy cell) and a real system (Cu electrodeposition in acidic CuSO sub 4 solution). Great similarity in the behaviour of the two systems was found. A simple way...

Full description

Saved in:
Bibliographic Details
Published inSurface technology Vol. 30; no. 4; pp. 405 - 413
Main Authors Maksimovic, M D, Zecevic, S K
Format Journal Article
LanguageEnglish
Published 01.05.1987
Online AccessGet full text

Cover

Loading…
More Information
Summary:The departure of the faradaic current from the total imposed periodically changing current has been investigated for both an ideal system (dummy cell) and a real system (Cu electrodeposition in acidic CuSO sub 4 solution). Great similarity in the behaviour of the two systems was found. A simple way is demonstrated to determine the upper frequency limit beyond which the beneficial effect of periodically changing range metal electrodeposition on the quality of the deposits can be obtained. 15 ref.--AA