W5 double prime Test: A simple method for measuring mean power output in the bench press exercise

The aims of the present study were to assess the validity and reliability of a novel simple test [Five Seconds Power Test (W5 double prime Test)] for estimating the mean power output during the bench press exercise at different loads, and its sensitivity to detect training-induced changes. Thirty tr...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of sport science Vol. 16; no. 8; pp. 940 - 947
Main Authors Tous-Fajardo, Julio, Moras, Gerard, Rodriguez-Jimenez, Sergio, Gonzalo-Skok, Oliver, Busquets, Albert, Mujika, Inigo
Format Journal Article
LanguageEnglish
Published 16.11.2016
Online AccessGet full text

Cover

Loading…
More Information
Summary:The aims of the present study were to assess the validity and reliability of a novel simple test [Five Seconds Power Test (W5 double prime Test)] for estimating the mean power output during the bench press exercise at different loads, and its sensitivity to detect training-induced changes. Thirty trained young men completed as many repetitions as possible in a time of approximately 5 s at 25%, 45%, 65% and 85% of one-repetition maximum (1RM) in two test sessions separated by four days. The number of repetitions, linear displacement of the bar and time needed to complete the test were recorded by two independent testers, and a linear encoder was used as the criterion measure. For each load, the mean power output was calculated in the W5 double prime Test as mechanical work per time unit and compared with that obtained from the linear encoder. Subsequently, 20 additional subjects (10 training group vs. 10 control group) were assessed before and after completing a seven-week training programme designed to improve maximal power. Results showed that both assessment methods correlated highly in estimating mean power output at different loads (r range: 0.86-0.94; p < .01) and detecting training-induced changes (R super(2): 0.78). Good to excellent intra-tester (intraclass correlation coefficient (ICC) range: 0.81-0.97) and excellent inter-tester (ICC range: 0.96-0.99; coefficient of variation range: 2.4-4.1%) reliability was found for all loads. The W5 double prime Test was shown to be a valid, reliable and sensitive method for measuring mean power output during the bench press exercise in subjects who have previous resistance training experience.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
content type line 23
ObjectType-Feature-2
ISSN:1746-1391
1536-7290
DOI:10.1080/17461391.2016.1184318