Measurements of water content and D/Hratio in apatite and silicate glasses using a NanoSIMS 50L
Water plays an important role in evolution of the Earth, Mars, Moon and other planets, with H isotopes used as a crucial tracer for fractionation processes and water reservoirs. In order to accurately and precisely measure water contents and D/Hratios of apatite and silicate glass with high lateral...
Saved in:
Published in | Journal of analytical atomic spectrometry Vol. 30; no. 4; pp. 967 - 978 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
01.03.2015
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Water plays an important role in evolution of the Earth, Mars, Moon and other planets, with H isotopes used as a crucial tracer for fractionation processes and water reservoirs. In order to accurately and precisely measure water contents and D/Hratios of apatite and silicate glass with high lateral resolution, we carried out a long term measurement with a NanoSIMS 50L, with special consideration for the H background, calibration of water content and instrumental mass fractionation. A detection limit of <10 ppm of water content has been achieved mainly by reducing the level of the H background, viaimproving vacuum and using a high primary beam current of up to 1 nA and a blanking technique. The measurements were carried out in three modes of detector configuration. In multicollection isotope mode, all super(1)H super(-), super(2)D super(-), super(12)C super(-) and super(18)O super(-) were measured simultaneously. Apatite and silicate glasses with water contents of <1.2 wt% were plotted on the same water content calibration curve with a slope of 0.704 plus or minus 0.037 (2SD). In peak jump isotope mode, super(1)H super(-), super(2)D super(-) and super(12)C super(-) were first measured simultaneously at a magnetic field BF1, and then super(18)O super(-) and other elements if needed at BF2 by switching the magnetic field. In this mode, apatite and MORB glass standards also share the same water content calibration curve with a slightly higher slope (0.786 plus or minus 0.054, 2SD) relative to that of the multicollection isotope mode. In these two isotope modes, apatite and silicate glass standards have similar instrumental mass fractionation of H isotopes within the analytical uncertainty (45ppt, 2SD) and similar precisions on water contents, however, the peak jump isotope mode can determine the volatile element contents and chlorine isotopes. In multicollection element mode, super(16)O super(1)H super(-) (for water content) and super(18)O super(-) were measured simultaneously, accompanied usually by other volatile elements. The slope of the water content calibration curve of apatite (3.727 plus or minus 0.112, 2SD) significantly differs from that of silicate glass (0.873 plus or minus 0.049, 2SD). Multicollection element mode can only determine the water and volatile element contents with two times higher sensitivity than that of two isotope modes. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 content type line 23 ObjectType-Feature-2 |
ISSN: | 0267-9477 1364-5544 |
DOI: | 10.1039/c4ja00417e |