Transrectal Drainage of Deep Pelvic Abscesses Using a Combined Transrectal Sonographic and Fluoroscopic Guidance

PURPOSE: To evaluate the feasibility and clinical efficacy of transrectal drainage of a deep pelvic abscess using combined transrectal sonographic and fluoroscopic guidance. MATERIALS AND METHODS: From March 1995 and August 2004, 17 patients (9 men; 8 women; mean age, 39years) suffering from pelvic...

Full description

Saved in:
Bibliographic Details
Published inUltrasonography (Seoul, Korea) Vol. 24; no. 3; p. 111
Main Authors Jeong, Kyung Soon, Jung, Gyoo Sik, Eun Jung Lee, Ji Ho Ko, Young Duk Joh
Format Journal Article
LanguageEnglish
Published Seoul Korean Society of Ultrasound in Medicine 01.09.2005
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:PURPOSE: To evaluate the feasibility and clinical efficacy of transrectal drainage of a deep pelvic abscess using combined transrectal sonographic and fluoroscopic guidance. MATERIALS AND METHODS: From March 1995 and August 2004, 17 patients (9 men; 8 women; mean age, 39years) suffering from pelvic pain, fever and leukocytosis were enrolled in this retrospective study. Ultrasound (US) or computed tomography (CT), which was obtained prior to the procedure, showed pelvic fluid collections that were deemed unapproachable by the percutaneous transabdominal routes. Transrectal drainage of the pelvic abscess was performed under combined transrectal sonographic and fluoroscopic guidance. The causes of the deep pelvic abscess were postoperative complications (n=7), complications associated with radiation (n=3) and chemotherapy (n=1) as well as unknown causes (n=6). A 7.5-MHz end-firing transrectal US probe with a needle biopsy guide attachment was advanced into the rectum. Once the abscess was identified, a needle was advanced via the biopsy guide and the abscess was punctured. Under US guidance, either a 0.018"or 0.035" guidewire was passed through the needle in the abscess. Under fluoroscopic guidance, the tract was dilated to the appropriate diameter with sequential fascial dilators, and a catheter was placed over the guide wire within the abscess. Clinical success of drainage was determined by a combination closure of the cavity on the follow up images and diminished leukocytosis. The technical and clinical success rate, complications, and patient's discomfort were analyzed. RESULTS: Drainage was technically successful in all patients and there were no serious complications. Surgery was eventually performed in two cases due to fistular formation with the rectum and leakage of the anastomosis site. The procedure was well tolerated in all but one patient who complained of discomfort while the catheter was inserted. The catheter did not interfere with defecation and there was no incidence of catheter expulsion by defecation. CONCLUSION: Transrectal drainage of deep pelvic abscesses using ultrasound and fluoroscopic guidance is a safe, feasible procedure that is well tolerated by patients and is relatively easy to perform.
ISSN:2288-5919
2288-5943