A FUNCTIONAL TEST PROGRAM FOR ASSESSING CORROSION PROBE'S PERFORMANCE

[...]pH was reduced from original value listed in Table 3 to approximately 6.0 by adding acetic acid and maintained for one week during which, probe readings were collected. [...]it was decided to decrease the pH to approximately 3.0 by adding hydrochloric acid and the pH was maintained at 3.0 for o...

Full description

Saved in:
Bibliographic Details
Published inNACE International Corrosion Conference Proceedings pp. 1 - 13
Main Authors Al-Shamari, Abdul Razzaq, Jarragh, Amer, Prakash, Surya, Mathusoothanan, S
Format Conference Proceeding
LanguageEnglish
Published Houston NACE International 01.01.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:[...]pH was reduced from original value listed in Table 3 to approximately 6.0 by adding acetic acid and maintained for one week during which, probe readings were collected. [...]it was decided to decrease the pH to approximately 3.0 by adding hydrochloric acid and the pH was maintained at 3.0 for one week. [...]the graph didn't show any corrosion trend. [...]it is evident that the ER probe with a 5 mil span works only if the corrosivity of the fluid is high and the data logging frequency is approaching the probe response time.