A Novel Platform for Radioimmunotherapy: Extracorporeal Depletion of Biotinylated and ^sup 90^Y-Labeled Rituximab in Patients with Refractory B-Cell Lymphoma

Radioimmunotherapy is limited by the absorbed dose to radiosensitive organs. Removal of circulating radiolabeled MAbs after tumor tissue has been optimally targeted and should permit the administration of higher radioactivity to patients, resulting in a higher absorbed tumor dose. A novel "extr...

Full description

Saved in:
Bibliographic Details
Published inCancer biotherapy & radiopharmaceuticals Vol. 20; no. 4; p. 457
Main Authors Lindén, Ola, Kurkus, Jan, Garkavij, Michael, Cavallin-Ståhl, Eva, Ljungberg, Michael, Nilsson, Rune, Ohlsson, Tomas, Sandberg, Bengt, Strand, Sven-Erik, Tennvall, Jan
Format Journal Article
LanguageEnglish
Published New Rochelle Mary Ann Liebert, Inc 01.08.2005
Online AccessGet full text

Cover

Loading…
More Information
Summary:Radioimmunotherapy is limited by the absorbed dose to radiosensitive organs. Removal of circulating radiolabeled MAbs after tumor tissue has been optimally targeted and should permit the administration of higher radioactivity to patients, resulting in a higher absorbed tumor dose. A novel "extracorporeal affinity adsorption treatment" (ECAT) device (MitraDep)was tested, with which biotinylated and radiolabeled MAbs can be removed from the circulation by passing whole blood over a filter coated with avidin. The antibodies were simultaneously radiolabeled and biotinylated using a trifunctional moiety comprising DOTA and biotin. Eight patients--all but 1 of whom with aggressive or mantle cell B-cell lymphoma-- who had failed to respond to standard therapies received infusions of 250 mg/m(2) cold rituximab and 150 MBq (111)In-rituximab-biotin for immunoscintigraphy. A week later, the patients were treated with another 250 mg/m(2) rituximab followed by (111)In/-(90)Y-rituximab-biotin (11 or 15 (90)Y MBq/kg). ECAT was performed 48 hours later. All 8 patients receiving (111)In-rituximab-biotin showed tumor uptake. Seven patients received radioimmunotherapy and subsequent ECAT. The mean depletion of (90)Y-rituximab-biotin in whole blood after ECAT was 96%, in the whole body 49%, in the lungs 62%, and in the liver and kidneys 40%. No effects on patients' vital signs and no adverse effects on hematological or coagulation parameters was observed during the ECAT procedure. A dose-escalation study is initiated.
ISSN:1084-9785
1557-8852
DOI:10.1089/cbr.2005.20.457