Evaluation of hydroxamate-based resins towards a more clinically viable 44Ti/44Sc radionuclide generator

For this research, several hydroxamate-based resins were synthesized and tested for use in 44Ti/44Sc generator systems in small scale experiments (740 kBq 44Ti). The most promising resin was tested further in larger scale generator studies (37 MBq). This resin displayed impressive retention of 44Ti...

Full description

Saved in:
Bibliographic Details
Published inApplied radiation and isotopes Vol. 192
Main Authors Gajecki, Leah, Marino, Celine M., Cutler, Cathy S., Sanders, Vanessa A.
Format Journal Article
LanguageEnglish
Published United States Elsevier 29.11.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:For this research, several hydroxamate-based resins were synthesized and tested for use in 44Ti/44Sc generator systems in small scale experiments (740 kBq 44Ti). The most promising resin was tested further in larger scale generator studies (37 MBq). This resin displayed impressive retention of 44Ti over several elutions, and high quantities of 44Sc were obtained in small volumes of dilute HCl eluents. Initial radiolabeling experiments were conducted and demonstrated the possibility of direct radiolabeling of the generator produced 44Sc with DOTA.
Bibliography:SC0012704
USDOE Office of Science (SC), Nuclear Physics (NP)
BNL-223912-2023-JAAM
ISSN:0969-8043
1872-9800