Module level EMC verification method for replacement items in nuclear power plant
Internal replaceable electronic module substitutions can impact EMC (ElectroMagnetic Compatibility) qualification testing and results if EMC testing is conducted at the cabinet level. The impact of component substitutions on EMC qualification results therefore should be evaluated. If a qualitative e...
Saved in:
Published in | Nuclear engineering and technology Vol. 55; no. 7; pp. 2407 - 2418 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | Korean |
Published |
2023
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Internal replaceable electronic module substitutions can impact EMC (ElectroMagnetic Compatibility) qualification testing and results if EMC testing is conducted at the cabinet level. The impact of component substitutions on EMC qualification results therefore should be evaluated. If a qualitative evaluation is not adequate to ensure that the modified product will not impact the cabinet level EMC qualification results, a new qualification testing should be conducted. Component level retesting should be conducted under electromagnetically equivalent conditions with the cabinet level test. This paper analyzes the propagation of conducted susceptibility test waveforms in a representative cabinet and evaluates the impact of component substitutions on cabinet level EMC qualification results according to the location of the replacement items. A guideline for a qualitative evaluation of the impact of component substitutions is described based on the propagation of the conducted susceptibility test waveforms. A module level test method is also described based on an analysis of the shielding effectiveness of the cabinet. |
---|---|
Bibliography: | KISTI1.1003/JNL.JAKO202323355317057 |
ISSN: | 1738-5733 2234-358X |