열화학적 CO 2 메탄화 등온반응기의 수순환 냉각시스템 설계
CFD analysis including optimization process was conducted to design shell and tube CO2 methanation reactor cooling system. The high-pressure saturated water flowed into the cooling system and was evaporated by heat flux from reacting tubes. The optimization process decided the gap between tubes and...
Saved in:
Published in | 한국수소 및 신에너지학회 논문집 Vol. 33; no. 4; pp. 451 - 461 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | Korean |
Published |
2022
|
Online Access | Get full text |
Cover
Loading…
Summary: | CFD analysis including optimization process was conducted to design shell and tube CO2 methanation reactor cooling system. The high-pressure saturated water flowed into the cooling system and was evaporated by heat flux from reacting tubes. The optimization process decided the gap between tubes and reactor diameter to satisfy objective functions related to temperature. The results showed that the gap and diameter reduced about 30% and 3.6% respectively. Averaged surface temperature satisfied the target value and the min-max deviation was minimized. |
---|---|
Bibliography: | KISTI1.1003/JNL.JAKO202225047342244 |
ISSN: | 1738-7264 |