Evaluation of cadmium ratio for conceptual design of a cyclotron-based thermal neutron radiography system

An approximate method for calculating the cadmium ratio of a cyclotron-based thermal neutron radiography system was developed. In this method, the Monte-Carlo code, MCNP6.2, was employed to calculate the neutron capture rates of Au-197, and the cadmium ratio was obtained by computing the ratio of ne...

Full description

Saved in:
Bibliographic Details
Published inNuclear engineering and technology Vol. 54; no. 7; pp. 2572 - 2578
Main Author Kuo, Weng-Sheng
Format Journal Article
LanguageKorean
Published 2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:An approximate method for calculating the cadmium ratio of a cyclotron-based thermal neutron radiography system was developed. In this method, the Monte-Carlo code, MCNP6.2, was employed to calculate the neutron capture rates of Au-197, and the cadmium ratio was obtained by computing the ratio of neutron capture rates. From the simulation results, the computed cadmium ratio is reasonably acceptable, and the assumption of ignoring the fast neutron contribution to the cadmium ratio is valid.
Bibliography:KISTI1.1003/JNL.JAKO202223158948967
ISSN:1738-5733
2234-358X