엔도크라운 디지털 인상을 위한 구강스캐너 3종의 정확도 평가: 실험실 연구

Purpose: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (IOSs) on digital impressions of different types of endocrown cavity preparations. Materials and methods: Two human mandibular molar teeth were prepared with different endocrown abutment design...

Full description

Saved in:
Bibliographic Details
Published inTaehan Chikwa Poch'ol Hakhoe chi Vol. 58; no. 4; pp. 282 - 289
Main Authors Ural, Cagri, Park, Ji-Man, Kaleli, Necati, Caglayan, Esma
Format Journal Article
LanguageKorean
Published 2020
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (IOSs) on digital impressions of different types of endocrown cavity preparations. Materials and methods: Two human mandibular molar teeth were prepared with different endocrown abutment designs: one with a buccal wall (Class 2) and the other without a buccal wall (Class 3). Both cavity designs were scanned using a reference desktop scanner (E3) and three different intraoral scanners: Trios3 (TRI group), Cerec Omnicam (CER group), and i500 (I5 group). The obtained Standard Tessellation Language (.stl) datasets were exported to metrology software. The precision was evaluated based on deviations among repeated scan models recorded by each IOS. The trueness was evaluated based on deviations between the reference data and repeated scans. For detecting interaction, data were statistically analyzed using a univariate analysis of variance (ANOVA) and for analyzing the comparison of the test groups data were analyzed by one-way ANOVA and post-hoc Tukey test at the significance level of .05. Results: The deviation values for both cavity designs in the I5 group were significantly lower than those in the other IOS groups in terms of trueness. For both cavity designs, the TRI group exhibited better precision than the other IOS groups. Conclusion: Different technologies of IOS device's and different endocrown prepration designs affected the accuracy of the digital scans. 목적:본 연구의 목표는 다른 유형의 엔도크라운(endocrown) 와동 형태를 세 가지 다른 구강스캐너로 디지털 인상을 채득하였을 때의 정확성을 평가하는 것이다. 재료 및 방법: 두 개의 인체 하악 대구치를 협측벽이 있는 것(Class 2)과 협측벽이 없는(Class 3), 두 가지 엔도크라운 지대주 디자인으로 치아형성 하였다. 와동 디자인 2종을 레퍼런스로 탁상용 스캐너(E3, 3shape)와 세 개의 다른 구강스캐너, Trios 3 (3shape, TRI group), Cerec Omnicam (Dentsply Sirona, CER group), i500 (Medit Corp., I5 group)로 스캔하였다. 표준 테셀레이션 언어(.stl) 데이터 세트를 얻어, 계측 소프트웨어에서 불러들였다. 각 구강스캐너로 획득한 반복된 스캔 데이터 사이의 편차에 기초하여 정밀도(precision)를 평가하였다. 기준 데이터와 반복하여 얻은 구강스캔 사이의 편차로서 진도(trueness)를 평가 하였다. 상호작용을 탐지하기 위해 데이터는 일변량 분산분석(ANOVA)을 사용하여 통계적으로 분석하였고, 실험군의 비교 분석을 위해 데이터는 .05의 유의 수준에서 일원 분산분석 및 사후 Tukey 테스트로 분석하였다. 결과: I5 군의 두 와동 형태에 대한 편차값은 진도의 측면에서 다른 구강스캐너 군에 비해 낮았다. 두 와동 디자인 모두에서 TRI 군은 다른 구강스캐너군 보다 우수한 정밀도를 보였다. 결론: 구강스캐너의 다양한 기술과 다양한 엔도크라운 치아형성 디자인이 디지털 스캔의 정확도에 영향을 미쳤다.
Bibliography:KISTI1.1003/JNL.JAKO202031563539588
ISSN:0301-2875