Plant Minimum Stable Load (Pmin) Test for Ilijan CCPP

This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load...

Full description

Saved in:
Bibliographic Details
Published inKEPCO Journal on electric power and energy Vol. 2; no. 1; pp. 83 - 88
Main Authors Kim, Si Moon, Yun, Wan No, Jang, Cheol Ho, Park, Se Ik
Format Journal Article
LanguageKorean
Published 2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load" [1]. This paper also contains the assessment of the impact of Pmin to plant operating parameters and possible technical operating issues when operating at lower loads and to recommend the safe minimum load operation of Ilijan per block. In addition, this paper describes the performance calculation results of efficiency and heat rate depending on the load level.
Bibliography:KISTI1.1003/JNL.JAKO201611962637851
ISSN:2465-8111
2466-0124