세탁기 드럼 내부의 습기 방출 메커니즘에 대한 수치 연구

Washing machine manufacturers typically advise consumers to maintain the relative humidity in the drum less than 80% for three days after the termination of a washing cycle in order to prevent bacteria proliferation. A vent installed in the back of a washing machine is used to release moisture to sa...

Full description

Saved in:
Bibliographic Details
Published in한국생산제조시스템학회지 Vol. 25; no. 1; pp. 54 - 61
Main Authors 정충효, 손덕영, 라선욱, 최윤호, Jung, Chung-Hyo, Sohn, Deok-Young, Na, Seon-Uk, Choi, Yun-Ho
Format Journal Article
LanguageKorean
Published 2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Washing machine manufacturers typically advise consumers to maintain the relative humidity in the drum less than 80% for three days after the termination of a washing cycle in order to prevent bacteria proliferation. A vent installed in the back of a washing machine is used to release moisture to satisfy this condition. Up to now, the design and installation of the vent have been based on experiments without understanding its roles and physical phenomena. In this study, various CFD results are presented in order to explain the physical mechanism of moisture release in a washing machine. Two methods of moisture release (diffusion and convection) were studied; diffusion was found to be the dominant process in removing moisture. Experiments were also performed to validate this behavior. In addition, this study will aid in the efficient design of vents to keep the relative humidity low inside the drum.
Bibliography:KISTI1.1003/JNL.JAKO201610254116492
ISSN:2233-6036
2383-4846