Experimental Study on the Characteristics of Rapid Chilled Converter Slag by Watering

In this study, a physical and chemical properties analysis was conducted for PCSP to evaluate properties of its materials and, for comparison purpose, was also conducted for CSP. The result of experiment confirmed improvement of iron recovery rate due to introduction of rapid water-cooling equipment...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of concrete structures and materials Vol. 5; no. 2; pp. 133 - 137
Main Authors Lee, Keun-Jae, Yoo, Seung-Yeup, Koo, Ja-Sul, Cho, Bong-Suk, Lee, Hoon-Ha
Format Journal Article
LanguageKorean
Published 2011
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this study, a physical and chemical properties analysis was conducted for PCSP to evaluate properties of its materials and, for comparison purpose, was also conducted for CSP. The result of experiment confirmed improvement of iron recovery rate due to introduction of rapid water-cooling equipment and greater density of exterior and interior structure through SEM observation and porosity measurement. Also, SEM, XRD and DSC-TGA analysis showed that content of f-CaO in PCSP was minuscule so it was decided that problems of material stability including f-CaO-caused bulging failure, which has been problematic, can be solved.
Bibliography:KISTI1.1003/JNL.JAKO201105462030679
ISSN:1976-0485
2234-1315