Determination of Capsaicinoids in Foods Using Ultra High Performance Liquid Chromatography
A sensitive, precise, and specific ultra high performance liquid chromatographic (u-HPLC) method was developed for the analysis of capsaicin in foods. The method validation parameters yielded good results, including linearity, precision, accuracy, and recovery. The u-HPLC separation was performed on...
Saved in:
Published in | Food science and biotechnology Vol. 19; no. 4; pp. 1005 - 1009 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | Korean |
Published |
2010
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A sensitive, precise, and specific ultra high performance liquid chromatographic (u-HPLC) method was developed for the analysis of capsaicin in foods. The method validation parameters yielded good results, including linearity, precision, accuracy, and recovery. The u-HPLC separation was performed on a reversed column $C_{18}$ (particle size 2 ${\mu}m$, i.d. 2 mm, length 50 mm, followed by fluorescence detection-excitation 280 nm, emission 325 nm). The recovery of capsaicin in gochujang was more than 91%, and the detection limit and lower determination limit of u-HPLC analysis were 0.054 and 0.163 ${\mu}g/mL$ for capsaicin and 0.053 and 0.160 ${\mu}g/mL$ for dihydrocapsaicin, respectively. The calibration graph for capsaicin and dihydrocapsaicin was linear from 0.2 to 10.0 ${\mu}g/mL$ for u-HPLC analysis. The inter-day and intra-day precisions (relative standard deviations) were <5.21% for capsaicin and <9.79% for dihydrocapsaicin while the average recoveries obtained were quantitative 91.1-94.8% for capsaicin, 91.4-97.0% for dihydrocapsacin, indicating good accuracy of the u-HPLC method. |
---|---|
Bibliography: | KISTI1.1003/JNL.JAKO201026064156549 |
ISSN: | 1226-7708 2092-6456 |