Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using a 20-Gauge Menghini Needle with a Lateral Forward Bevel and a 22-Gauge Franseen Needle: A Single-Center Large Cohort Study
Background/Aims: Several fine-needle biopsy (FNB) needles are available for endoscopic ultrasound (EUS)-guided tissue acquisition. However, there is disagreement on which type of needle has the best diagnostic yield. The aim of this study was to compare the performance and safety of two commonly use...
Saved in:
Published in | Clinical endoscopy Vol. 54; no. 5; pp. 730 - 738 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | Korean |
Published |
대한소화기내시경학회
30.09.2021
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background/Aims: Several fine-needle biopsy (FNB) needles are available for endoscopic ultrasound (EUS)-guided tissue acquisition. However, there is disagreement on which type of needle has the best diagnostic yield. The aim of this study was to compare the performance and safety of two commonly used EUS-FNB needles.
Methods: We retrospectively analyzed consecutive patients who underwent EUS-FNB between June 2016 and March 2020 in our hospital. Two types of needles were evaluated: a 20-gauge Menghini needle with a lateral forward bevel and a 22-gauge Franseen needle. Rapid on-site evaluation was performed in all the cases. A multivariate analysis was performed to clarify the negative predictive factors for obtaining a histological diagnosis. Propensity score matching was performed to compare the diagnostic yields of these two needles.
Results: We analyzed 666 patients and 690 lesions. The overall diagnostic rate of histology alone was 88.8%, and the overall adverse event rate was 1.5%. Transduodenal access and small lesions (≤2 cm) were identified as negative predictive factors for obtaining a histological diagnosis. After propensity score matching, 482 lesions were analyzed. The diagnostic accuracy rates of histology in the M and F needle groups were 89.2% and 88.8%, respectively (p=1.00).
Conclusions: Both the needles showed high diagnostic yield, and no significant difference in performance was observed between the two. Clin Endosc 2021;54:730-738 |
---|---|
Bibliography: | The Korean Society of Gastrointestinal Endoscopy |