A technique for estimating detection limits of radio-nuclide identifying detectors by means of computer simulations
A simulation technique has been developed to study the performance of nuclide identifying gamma detector units operating under a variety of different conditions. The studies are related to nuclide identification based on a template matching algorithm which has been well established, in particular, f...
Saved in:
Published in | 2008 IEEE Nuclear Science Symposium Conference Record pp. 648 - 655 |
---|---|
Main Authors | , , , , , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.10.2008
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A simulation technique has been developed to study the performance of nuclide identifying gamma detector units operating under a variety of different conditions. The studies are related to nuclide identification based on a template matching algorithm which has been well established, in particular, for the analysis of low statistics measurements. Results are presented for hand-held devices equipped with NaI(Tl) and LaBr 3 (Ce 3+ ) scintillation detectors, respectively |
---|---|