Detection of T wave beta-to-beat variations prior to ventricular arrythmias onset in ICD-stored intracardiac electrograms: the endocardial T-wave alternans study (ETWAS)

Background: The aim of the Endocardial T-Wave Alternans Study was to prospectively assess thepresence of T-wave alternans (TWA) or beat-to-beat repolarization changes on implantable cardioverter-defibrillator (ICD)-stored electrograms (EGMs) immediately preceding the onset of spontaneous ventricular...

Full description

Saved in:
Bibliographic Details
Published inPacing and clinical electrophysiology Vol. 37; no. 11; pp. 1510 - 1519
Main Authors Maury, Philippe, Lin, Chao, Pasquié, Jean Luc, Raczka, Franck, Taieb, Jérôme, Mailhes, Corinne, Tourneret, Jean-Yves, Rollin, Anne, Duparc, Alexandre, Mondoly, Pierre, Winum, Pierre, Rolland, Philippe, Castanié, Francis
Format Journal Article
LanguageEnglish
Published Wiley 2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background: The aim of the Endocardial T-Wave Alternans Study was to prospectively assess thepresence of T-wave alternans (TWA) or beat-to-beat repolarization changes on implantable cardioverter-defibrillator (ICD)-stored electrograms (EGMs) immediately preceding the onset of spontaneous ventriculartachycardia (VT) or fibrillation (VF). Methods: Thirty-seven VT/VF episodes were compared to 116 baseline reference EGMs from the same57 patients. A Bayesian model was used to estimate the T-wave waveform in each cardiac beat and a setof 10 parameters was selected to segment each detected T wave. Beat-by-beat differences in each T-waveparameter were computed using the absolute value of the difference between each beat and the followingone. Fisher criterion was used for determining the most discriminant T-wave parameters, then top-Mranked parameters yielding a normalized cumulative Fisher score>95% were selected, and analysis wasapplied on these selected parameters. Simulated TWA EGMs were used to validate the algorithm. Results: In the simulation study, TWA was detectable even in the case of the smallest simulatedalternans of 25μV. In 13 of the 37 episodes (35%) occurring in nine of 16 patients, significant largerbeat-to-beat variations before arrhythmia onset were detected compared to their respective references(median one positive episode per patient). Parameters including the T-wave apex amplitude seem themore discriminant parameters.Conclusions:Detection of beat-by-beat repolarization variations in ICD-stored EGMs is feasible ina significant subset of cases and may be used for predicting the onset of ventricular arrhythmias.
ISSN:0147-8389
1540-8159
DOI:10.1111/pace.12453