Effects of BURP Maneuver on the Hemodynamics and QT and P Dispersions in ECG in Cardiac Surgery Patients
Effects of BURP Maneuver on the Hemodynamics and QT and P Dispersions in ECG in Cardiac Surgery PatientsObjective: In this study, we aimed to investigate the possible effects of “backward-upward right-sided pressure” (BURP) maneuver applied during tracheal intubation (TI) in patients who will underg...
Saved in:
Published in | Göğüs-Kalp-Damar Anestezi ve Yoğun Bakım Derneği Dergisi; Sayı: 1; 27-32 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | Turkish |
Published |
Göğüs-Kalp-Damar Anestezi ve Yoğun Bakım Derneği Dergisi
01.03.2014
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Summary: | Effects of BURP Maneuver on the Hemodynamics and QT and P Dispersions in ECG in Cardiac Surgery PatientsObjective: In this study, we aimed to investigate the possible effects of “backward-upward right-sided pressure” (BURP) maneuver applied during tracheal intubation (TI) in patients who will undergo coronary artery baypas surgery on hemodynamic response and QT dispersion (QTd) and P wave dispersion (Pd).Material and Methods: 40 patients undergoing elective coronary artery bypas graft surgery were included in this study. Patients were divided into 2 groups as Group C (control group, n=20) and Group B (BURP group, n=20). Standard 12-lead electrocardiogram (ECG) was performed before induction. This ECG was recorded and accepted as the baseline (EKG0). BURP maneuver was performed only on patients in group B, during laryngoscopy. 12-lead ECG recordings of the patients were also performed at 1 min (EKG1) and 3 min (EKG3) after intubation. The two groups were compared in terms of hemodynamic parameters, QTd and Pd. Results: Demographic data were similar between groups (p>0.05). Duration of intubation was similar in groups C and B (p>0.05). There was no statistically significant difference between groups in terms of heart rate (HR) and mean arterial pressures (MAP), QTd and Pd dispersions during the follow-up time (p> 0.05). Conclusion: We did not observe any effect of BURP maneuver on QTd or Pd in ECG or on hemodynamic parameters such as HR and MAP in patients undergoing coronary artery bypass surgery.
Amaç: Amacımız koroner arter baypas cerrahisinde laringoskopi ve trakeal entübasyon (TE) sırasında uygulanan “backward upward right-sided pressure” (BURP) manevrasının, QT dispersiyon (OTd), P dispersiyon (Pd) ve hemodinamik yanıt üzerindeki olası etkilerini araştırmaktır. Gereç ve Yöntem: Çalışmaya elektif koroner arter baypas greft cerrahisi geçiren 40 hasta alındı. Hastalar Grup K (kontrol grubu, n=20) ve Grup B (BURP grubu, n=20) olarak 2 gruba ayrıldı. Hastalara premedikasyon yapıldıktan sonra standart 12 derivasyonlu elektrokardiyografi (EKG) bağlanarak indüksiyon öncesi EKG çekildi. Bu EKG bazal (EKG0) kabul edilerek kaydedildi. Yalnızca BURP grubundaki hastalara laringoskopi sırasında BURP manevrası yapıldı. Hastaların 12 derivasyonlu EKG kayıtları entübasyon sonrası 1. dk. (EKG1) ve 3. dk. (EKG3)’ larda da alındı ve iki grup QTd ve Pd açısından karşılaştırıldı.Bulgular: Gruplar arasında demografik veriler benzerdi. (p >0.05). Grup K ve grup B’nin entübasyon süreleri benzerdi (p >0.05). Kalp hızları (KH), ortalama arter basınçlarının (OAB), izlem zamanları içindeki QTd ve Pd’de gruplar arasında istatistiksel olarak anlamlı farklılık gözlenmedi (p >0.05).Sonuç: Koroner arter baypas cerrahisi geçirecek hastalarda BURP manevrasının KH ve OAB değerleri ile EKG’deki QTd ve Pd üzerine etkisinin olmadığını gözlemledik. |
---|---|
Bibliography: | http://dergipark.ulakbim.gov.tr/gokalpdayog/article/view/5000062871 |
ISSN: | 1305-5550 |