Poolside Activity Measurement of Cobalt Target

To obtain cobalt target activity data after a cycle of irradiation in a pressurized water reactor, the cobalt target dose distribution was measured underwater using alanine dosimeters. The effects of cobalt target structure, water medium, measurement device, operation, and environment were corrected...

Full description

Saved in:
Bibliographic Details
Published inTong wei su Vol. 37; no. 3; pp. 17 - 23
Main Author YIN Zhenguo1, LIAN Qi2, ZHANG Ping1, XU Bei2, WANG Mingming2, FENG Wuzhou1, YAN Tianyu1
Format Journal Article
LanguageChinese
Published Editorial Board of Journal of Isotopes 01.02.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To obtain cobalt target activity data after a cycle of irradiation in a pressurized water reactor, the cobalt target dose distribution was measured underwater using alanine dosimeters. The effects of cobalt target structure, water medium, measurement device, operation, and environment were corrected using Monte Carlo calculations. The feasibility of the method and device was confirmed through both experimental and Monte Carlo comparison. The underwater measurement data of cobalt target activity matches the theoretical calculated values, with an uncertainty of 6.5%.
ISSN:1000-7512