Validation of a novel device to objectively measure adherence to long-term oxygen therapy

Sun-Kai V Lin1, Daniel K Bogen1, Samuel T Kuna2,31Department of Bioengineering; 2Department of Medicine, Pulmonary, Allergy and Critical Care Division, and Center for Sleep and Respiratory Neurobiology, University of Pennsylvania, Pennsylvania, USA; 3Department of Medicine, Philadelphia Veterans Aff...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of chronic obstructive pulmonary disease Vol. 2008; no. Issue 3; pp. 435 - 442
Main Authors Sun-Kai V Lin, Daniel K Bogen, Samuel T Kuna
Format Journal Article
LanguageEnglish
Published Dove Medical Press 01.10.2008
Online AccessGet full text

Cover

Loading…
More Information
Summary:Sun-Kai V Lin1, Daniel K Bogen1, Samuel T Kuna2,31Department of Bioengineering; 2Department of Medicine, Pulmonary, Allergy and Critical Care Division, and Center for Sleep and Respiratory Neurobiology, University of Pennsylvania, Pennsylvania, USA; 3Department of Medicine, Philadelphia Veterans Affairs Medical Center Philadelphia, Pennsylvania, USARationale: We have developed a novel oxygen adherence monitor that objectively measures patient use of long-term oxygen therapy. The monitor attaches to the oxygen source and detects whether or not the patient is wearing the nasal cannula.Objective: The study’s purpose was to validate the monitor’s performance in patients with chronic obstructive pulmonary disease during wakefulness and sleep.Methods: Ten adult males with stable chronic obstructive pulmonary disease (mean ± SD FEV1 37.7 ± 14.9% of predicted) on long-term continuous oxygen therapy were tested in a sleep laboratory over a 12–13 hour period that included an overnight polysomnogram.Measurements: The monitor’s measurements were obtained at 4-minute intervals and compared to actual oxygen use determined by review of time-synchronized video recordings.Main results: The monitor made 1504/1888 (79.7%) correct detections (unprocessed data) across all participants: 957/1,118 (85.6%) correct detections during wakefulness and 546/770 (70.9%) during sleep. All errors were false negatives, ie, the monitor failed to detect that the participant was actually wearing the cannula. Application of a majority-vote filter to the raw data improved overall detection accuracy to 84.9%.Conclusions: The results demonstrate the monitor’s ability to objectively measure whether or not men with chronic obstructive pulmonary disease are receiving their oxygen treatment. The ability to objectively measure oxygen delivery, rather than oxygen expended, may help improve the management of patients on long-term oxygen therapy.Keywords: chronic obstructive pulmonary disease
ISSN:1176-9106
1178-2005