Extraction and determination of trace amounts of cadmium in aqueous solutions using organic gas steam liquid extraction method

In this study, organic gas steam liquid extraction (OGS-LE) by using a particular homemade extraction cell was proposed to extract and determine cadmium in aqueous solutions. The variables of interest in the OGS-LE method in this research are extraction solvent volume, pH of the aqueous solution, th...

Full description

Saved in:
Bibliographic Details
Published inمجله علوم و فنون هسته‌ای Vol. 43; no. 4; pp. 118 - 124
Main Authors S. Rasouli Garmarodi, A. Nilchi, M.R. Yaftian, J. Rafiei
Format Journal Article
LanguagePersian
Published Nuclear Science and Technology Research Institute 01.12.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this study, organic gas steam liquid extraction (OGS-LE) by using a particular homemade extraction cell was proposed to extract and determine cadmium in aqueous solutions. The variables of interest in the OGS-LE method in this research are extraction solvent volume, pH of the aqueous solution, the molar ratio of extractant agent, and heated chamber temperature, which were investigated. Under the optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) of this method were found to be 0.03 μg L−1 and 0.09 μg L−1 for Cd2+ ions. The linear concentration range was 0.1-1 μg L−1 , and the percent relative standard deviation (RSD %) was 3.7%.
ISSN:1735-1871
2676-5861
DOI:10.24200/nst.2022.1474