Inter-eye comparison of retinal oximetry and vessel caliber between eyes with asymmetrical glaucoma severity in different glaucoma subtypes

Clarissa Shu Ming Cheng,1,2 Yi Fang Lee,2 Charles Ong,3 Zhu Li Yap,2 Andrew Tsai,2 Aditi Mohla,2 Monisha E Nongpiur,4 Tin Aung,2,4 Shamira A Perera2,4 1Department of Ophthalmology, Tan Tock Seng Hospital, 2Department of Ophthalmology, Singapore National Eye Centre, 3Yong Loo Lin School of Medicine,...

Full description

Saved in:
Bibliographic Details
Published inClinical ophthalmology (Auckland, N.Z.) Vol. 2016; no. Issue 1; pp. 1315 - 1321
Main Authors Cheng CS, Lee YF, Ong C, Yap ZL, Tsai A, Mohla A, Nongpiur ME, Aung T, Perera SA
Format Journal Article
LanguageEnglish
Published Dove Medical Press 01.07.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Clarissa Shu Ming Cheng,1,2 Yi Fang Lee,2 Charles Ong,3 Zhu Li Yap,2 Andrew Tsai,2 Aditi Mohla,2 Monisha E Nongpiur,4 Tin Aung,2,4 Shamira A Perera2,4 1Department of Ophthalmology, Tan Tock Seng Hospital, 2Department of Ophthalmology, Singapore National Eye Centre, 3Yong Loo Lin School of Medicine, National University of Singapore, 4Singapore Eye Research Institute, Singapore National Eye Centre, Singapore Background: To compare retinal vessel oxygenation and vessel caliber in primary angle-closure glaucoma (PACG), primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG), and normal controls, as well as between eyes of asymmetrical glaucoma severity.Methods: This was a prospective, cross-sectional study. The 159 subjects (PACG, n=39; POAG, n=41; NTG, n=41; normal controls, n=38) underwent retinal oxygen saturation measurements using the Oxymap T1 Retinal Oximeter, optical coherence tomography, and Humphrey visual field testing. Retinal oxygen saturation and vessel diameter were compared between the glaucoma groups and normal controls, as well as between eyes of asymmetrical glaucoma severity. Kruskal-Wallis test was performed for comparison among different subtypes of glaucoma. Wilcoxon signed-rank test was used to compare the inter-eye differences.Results: Compared to normal controls, arteriolar oxygen saturation was increased in PACG eyes (P=0.048) but not in POAG or NTG eyes. There were no significant differences in oxygen saturation in venules or arteriovenous (AV) difference in all three glaucoma groups. Venular diameter was significantly reduced in all glaucoma groups compared to normal controls (P<0.001), but no such change was observed in arteriolar diameter (P=0.10). When comparing between eyes of asymmetrical glaucoma severity, arteriolar oxygen saturation (P=0.03) and AV difference (P=0.04) were significantly higher, while arteriolar diameter was significantly lower (P=0.001) in the worse eye in PACG group. There were no significant differences in oximetric parameters or vessel calibers between the worse and the better eyes in POAG and NTG groups. Conclusion: Eyes with PACG showed increased arteriolar oxygen saturation and increased AV difference. This was not observed in POAG and NTG eyes. Arteriolar diameter in PACG and venular diameter in all three glaucoma groups were reduced. The difference observed in PACG eyes may be due to an increased metabolic demand in the disease process compared to open-angle glaucoma. Keywords: glaucoma, oximetry, retinal vessels, imaging
ISSN:1177-5483