Infection management in the extravascular implantable cardioverter defibrillator: experience from the EV ICD Pivotal study

Abstract Background The extravascular implantable cardioverter defibrillator (EV ICD) has recently emerged as an option for guideline indicated ICD patients. Results from the EV ICD Pilot and Pivotal studies demonstrated that the device can provide safe and effective therapy through chronic follow u...

Full description

Saved in:
Bibliographic Details
Published inEuropean heart journal Vol. 45; no. Supplement_1
Main Authors Clementy, N, Crozier, I, Murgatroyd, F, Boersma, L V A, Manlucu, J, Knight, B P, Leclercq, C, Birgersdotter-Green, U M, Mattioni, T, Sholevar, D, Hersi, A, Wiggenhorn, C, Friedman, P
Format Journal Article
LanguageEnglish
Published 28.10.2024
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Background The extravascular implantable cardioverter defibrillator (EV ICD) has recently emerged as an option for guideline indicated ICD patients. Results from the EV ICD Pilot and Pivotal studies demonstrated that the device can provide safe and effective therapy through chronic follow up. Lead placement outside the vasculature has the potential to reduce systemic infections. Infection occurrence and management details from the Pivotal are reported. Purpose To report on details of infection occurrence and management from the EV ICD Pivotal study. Methods The EV ICD Pivotal study was an international, prospective, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Results In the EV ICD Pivotal study, 316 patients had an implant attempt, (74.7% male, age 53.8±13.1 years, 82% primary prevention, LVEF of 38.9%±15.4%, and NYHA Class I [23.7%] or II/III [65.5%]), of which 15 had a system or procedure-related infection (4.7%, 9 - 737 days post-implant) through an average 16.2 months follow-up. Of these infections, 8 were classified as major complications, 3 as minor, and 4 as observations. Most (n=9) infections were addressed through medication with or without wound care (2.8% of patients) while 6 (1.9% of patients) resulted in system removal. There was a single lead-related infection addressed through system explant. However, there were no reports of mediastinitis, sepsis, or endocarditis. No system removal resulted in sequelae. Conclusions Infection rates observed in the EV ICD Pivotal study were similar to those reported in the subcutaneous implantable cardioverter defibrillator. The results from this study support that EV ICD related infections are treatable with antibiotic therapy or system removal. No system or procedure-related systemic infections such as mediastinitis, sepsis, or endocarditis have been reported in the Pivotal study.
ISSN:0195-668X
1522-9645
DOI:10.1093/eurheartj/ehae666.746