水洗系统脱除沼气中的CO2(英文)
CO2 removal from biogas by water washing system was investigated with various parameters,including liquid/gas ratio,pressure,temperature,and CO2 content.The results indicate that CO2 removal ratio could reach 34.6%-94.2%as liquid/gas ratio increased from 0.14 to 0.50.Increasing pressure(from 0.8 to...
Saved in:
Published in | 中国化学工程学报:英文版 no. 8; pp. 950 - 953 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
2014
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | CO2 removal from biogas by water washing system was investigated with various parameters,including liquid/gas ratio,pressure,temperature,and CO2 content.The results indicate that CO2 removal ratio could reach 34.6%-94.2%as liquid/gas ratio increased from 0.14 to 0.50.Increasing pressure(from 0.8 to 1.2 MPa) could improve gas purification with a constant inflow rate of gas.Temperature played a key role in the process and lower temperature in absorption tower was beneficial for reducing CO2 content.CO2 removal ratio could reach 24.4%-83.2%when CO2 content in the simulated gas was 25%-45%.The lowest CO2 content after absorption was 2.6%at1.2 MPa with 400 L·h-1 gas flow and 200 L·h-1 water flow,which meets the requirement of CO2 content in natural gas for vehicle fuel. |
---|---|
Bibliography: | 11-3270/TQ Yong Xiao;Hairong Yuan;Yunzhi Pang;Shulin Chen;Baoning Zhu;Dexun Zou;Jingwei Ma;Liang Yu;Xiujin Li;Centre for Resource and Environmental Research,Beijing University of Chemical Technology;Department of Biological Systems Engineering,Washington State University,Pullman,WA 99164,USA |
ISSN: | 1004-9541 2210-321X |