Synthesis and properties of three novel rhodamine-based fluorescent sensors for Hg^2

Three novel rhodamine-based Hg^2+ fluorescent sensors were designed and synthesized. The sensors could work in semi-aqueous solutions with nearly neutral p H and showed high selectivity and sensitivity to Hg^2+ with remarkable fluorescence enhancement. For these three sensors, the linear working ran...

Full description

Saved in:
Bibliographic Details
Published in中国化学快报:英文版 no. 6; pp. 989 - 992
Main Author Miao-Miao Hong Ai-Feng Liu Ying Xu Dong-Mei Xu
Format Journal Article
LanguageEnglish
Published 2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Three novel rhodamine-based Hg^2+ fluorescent sensors were designed and synthesized. The sensors could work in semi-aqueous solutions with nearly neutral p H and showed high selectivity and sensitivity to Hg^2+ with remarkable fluorescence enhancement. For these three sensors, the linear working range broadened(0–80, 0–100 and 0–140 μmol/L, respectively) and the sensitivity increased(7.7, 15.5 and 17.6 folds of the fluorescence enhancement and 512, 66.2 and 37.6 ppb of the detection limit) with the rising of the thiourea-unit numbers. Furthermore the sensors exhibited excellent interference immunity to multiple environmentally and biologically relevant metal ions. Pond and tap water assay showed good practicability of the sensors. The number of the bound Hg~(2+) equaling to that of the thiourea units and the irreversible recognition process implied a new interaction way between Hg~(2+) and the sensor.
Bibliography:11-2710/O6
Rhodamine; Polyethylenepolyamine; Thiourea; Fluorescent sensor; Hg2
Three novel rhodamine-based Hg^2+ fluorescent sensors were designed and synthesized. The sensors could work in semi-aqueous solutions with nearly neutral p H and showed high selectivity and sensitivity to Hg^2+ with remarkable fluorescence enhancement. For these three sensors, the linear working range broadened(0–80, 0–100 and 0–140 μmol/L, respectively) and the sensitivity increased(7.7, 15.5 and 17.6 folds of the fluorescence enhancement and 512, 66.2 and 37.6 ppb of the detection limit) with the rising of the thiourea-unit numbers. Furthermore the sensors exhibited excellent interference immunity to multiple environmentally and biologically relevant metal ions. Pond and tap water assay showed good practicability of the sensors. The number of the bound Hg~(2+) equaling to that of the thiourea units and the irreversible recognition process implied a new interaction way between Hg~(2+) and the sensor.
ISSN:1001-8417
1878-5964