对乙酞氨基酚和色氨酸存在下采用改进的碳纳米管糊电极伏安法测定抗坏血酸(英文)

A carbon paste electrode (CPE) modified with carbon nanotubes and 5‐amino‐3’,4’‐dimethyl‐ bi‐ phenyl‐2‐ol (5ADB) is prepared. Under the optimum pH of 7.0, the oxidation of ascorbic acid (AA) on the modified CPE occurs at a potential about 280 mV less positive than that on the unmodified CPE. Some ki...

Full description

Saved in:
Bibliographic Details
Published in催化学报 no. 6; pp. 1098 - 1104
Main Author Hadi BEITOLLAHI Somayeh MOHAMMADI
Format Journal Article
LanguageChinese
Published 2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A carbon paste electrode (CPE) modified with carbon nanotubes and 5‐amino‐3’,4’‐dimethyl‐ bi‐ phenyl‐2‐ol (5ADB) is prepared. Under the optimum pH of 7.0, the oxidation of ascorbic acid (AA) on the modified CPE occurs at a potential about 280 mV less positive than that on the unmodified CPE. Some kinetic and thermodynamic parameters for electrocatalytic oxidation of AA, including electron transfer coefficient (α = 0.58) and diffusion coefficient (D = 2.2 × 10-6 cm2/s), are also determined. AA, acetaminophen (AC), and tryptophan (TRP) were detected simultaneously using the modified CPE. The peak potentials recorded using the modified CPE in phosphate‐buffered solution at pH 7.0 were 265, 465, and 780 mV for AA, AC, and TRP, respectively. The modified CPE was successfully used to determine the concentrations of AA, AC, and TRP in real samples.
Bibliography:A carbon paste electrode (CPE) modified with carbon nanotubes and 5‐amino‐3’,4’‐dimethyl‐ bi‐ phenyl‐2‐ol (5ADB) is prepared. Under the optimum pH of 7.0, the oxidation of ascorbic acid (AA) on the modified CPE occurs at a potential about 280 mV less positive than that on the unmodified CPE. Some kinetic and thermodynamic parameters for electrocatalytic oxidation of AA, including electron transfer coefficient (α = 0.58) and diffusion coefficient (D = 2.2 × 10–6 cm2/s), are also determined. AA, acetaminophen (AC), and tryptophan (TRP) were detected simultaneously using the modified CPE. The peak potentials recorded using the modified CPE in phosphate‐buffered solution at pH 7.0 were 265, 465, and 780 mV for AA, AC, and TRP, respectively. The modified CPE was successfully used to determine the concentrations of AA, AC, and TRP in real samples.
Ascorbic acid Acetaminophen Tryptophan Carbon nanotube paste electrode Electrocatalysis
21-1195/O6
Hadi BEITOLLAHI a,*,Somayeh MOHAMMADI b a Environment Department,Institute
ISSN:0253-9837
1872-2067