Design and assembly of the CsI(T1) crystal module of the BESⅢ electro-magnetic calorimeter
The CsI(T1) crystal modules of the Beijing Spectrometer Ⅲ (BESⅢ) electro-magnetic calorimeter (EMC) were designed and assembled through Monte Carlo simulation and experiments. After the assembly was finished, the performance of each crystal module was tested by cosmic rays. All crystal modules were...
Saved in:
Published in | Chinese physics C Vol. 32; no. 11; pp. 908 - 911 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
2008
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The CsI(T1) crystal modules of the Beijing Spectrometer Ⅲ (BESⅢ) electro-magnetic calorimeter (EMC) were designed and assembled through Monte Carlo simulation and experiments. After the assembly was finished, the performance of each crystal module was tested by cosmic rays. All crystal modules were found to work well before the installation of EMC. |
---|---|
Bibliography: | O56 BESⅢ electro-magnetic calorimeter, CsI(T1) crystal, crystal module 11-5641/O4 |
ISSN: | 1674-1137 0254-3052 |