About the Experimental and Virtual Analysis of Orthopedic Implant Systems for the Revision of the Hip Prosthesis with Morcellated Bone Graft and Reconstruction Net

INTRODUCTIONProsthesis loosening is an alteration of the function and position of a total hip prosthesis with reference to the initial surgical moment. The main mechanism unanimously accepted for aseptic prosthetic losses at the level of the cup is represented by the biological mechanism. MATERIAL A...

Full description

Saved in:
Bibliographic Details
Published inCurrent health sciences journal Vol. 47; no. 2; pp. 249 - 255
Main Authors Călin, Daniel Cosmin, Popa, Dragoş Laurenţiu, Grecu, Alexandru Florian, Grecu, Dan Cristian, Nemeş, Răducu Nicolae, Buciu, Gabriel
Format Journal Article
LanguageEnglish
Published Medical University Publishing House Craiova 01.04.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:INTRODUCTIONProsthesis loosening is an alteration of the function and position of a total hip prosthesis with reference to the initial surgical moment. The main mechanism unanimously accepted for aseptic prosthetic losses at the level of the cup is represented by the biological mechanism. MATERIAL AND METHODExperimental and virtual, interdisciplinary tools, techniques and methods were used to determine the behavior of the hip replacement prosthesis with the morcellated graft and the reconstruction net. Performing an orthopedic assembly with a morcellated bone graft and reconstruction net. An assembly was performed on a hip joint taken from an animal (cow). The biological material and the components of the prosthesis were prepared similarly to the revision prosthesis intervention. Experimental testing of orthopedic assembly with morcellated bone graft and reconstruction net. This assembly was tested on a universal machine to determine the maximum force at which it yields. This was 1790 Kgf, i.e. 17559 N. Virtual experimental testing of the hip joint with orthopedic revision assembly with a morcellated bone graft and reconstruction net for normal gait loading. The orthopedic assembly with the morcellated graft and the reconstruction net was reconstructed in the virtual environment. Normal load was used. Results maps were obtained. CONCLUSIONSAnalyzing the results from the two tests, experimental and virtual, and important conclusions were drawn regarding this orthopedic assembly.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2067-0656
2069-4032
DOI:10.12865/CHSJ.47.02.15