Simple method to measure OSNR in transmission systems with channel filtering
A simple method to estimate the OSNR in transmission systems with a strong channel filtering and spectral broadening is presented. The method uses the measured spectra from optical channel monitors at optical add-drop multiplexer and dynamic gain equaliser locations and requires no additional equipm...
Saved in:
Published in | Electronics letters Vol. 42; no. 7; p. 1 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
Stevenage
John Wiley & Sons, Inc
30.03.2006
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A simple method to estimate the OSNR in transmission systems with a strong channel filtering and spectral broadening is presented. The method uses the measured spectra from optical channel monitors at optical add-drop multiplexer and dynamic gain equaliser locations and requires no additional equipment. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0013-5194 1350-911X |