Echography and computed tomography in the evaluation and follow-up of uterine cancers
In this review of 139 cancers of the cervix uteri and 43 cancers of the corpus uteri, the authors compare clinical, sonographic and CT data. For the 58 patients with cervical cancer who presented infiltration of the parametrium at physical examination under general anesthesia, sonography gave 11 fal...
Saved in:
Published in | Bulletin du cancer Vol. 77; no. 7; p. 689 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | French |
Published |
France
1990
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Summary: | In this review of 139 cancers of the cervix uteri and 43 cancers of the corpus uteri, the authors compare clinical, sonographic and CT data. For the 58 patients with cervical cancer who presented infiltration of the parametrium at physical examination under general anesthesia, sonography gave 11 false negative errors while CT gave 8 false positives. By contrast, for the 47 tumors staged IIb after examination under general anesthesia, sonography disclosed additional abnormalities in 20 cases and CT in 22 cases. A series of 52 disease recurrences in patients who had received curative treatment for uterine cancer was also reviewed; overall, an association of physical examination and ultrasonography had the same value as CT. In light of these results, the authors propose an algorithm for the exploration of uterine cancers in which the results of physical examination condition examination by ultrasonography or CT. |
---|---|