Phase‐based masking for quantitative susceptibility mapping of the human brain at 9.4T
Purpose To develop improved tissue masks for QSM. Methods Masks including voxels at the brain surface were automatically generated from the magnitude alone (MM) or combined with test functions from the first (PG) or second (PB) derivative of the sign of the wrapped phase. Phase images at 3T and 9.4T...
Saved in:
Published in | Magnetic resonance in medicine Vol. 88; no. 5; pp. 2267 - 2276 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Wiley Subscription Services, Inc
01.11.2022
|
Subjects | |
Online Access | Get full text |
ISSN | 0740-3194 1522-2594 1522-2594 |
DOI | 10.1002/mrm.29368 |
Cover
Summary: | Purpose
To develop improved tissue masks for QSM.
Methods
Masks including voxels at the brain surface were automatically generated from the magnitude alone (MM) or combined with test functions from the first (PG) or second (PB) derivative of the sign of the wrapped phase.
Phase images at 3T and 9.4T were simulated at different TEs and used to generate a mask, PItoh, with between‐voxel phase differences less than π. MM, PG, and PB were compared with PItoh. QSM were generated from 3D multi‐echo gradient‐echo data acquired at 9.4T (21 subjects aged: 20‐56y), and from the QSM2016 challenge 3T data using different masks, unwrapping, background removal, and dipole inversion algorithms. QSM contrast was quantified using age‐based iron concentrations.
Results
Close to air cavities, phase wraps became denser with increasing field and echo time, yielding increased values of the test functions. Compared with PItoh, PB had the highest Dice coefficient, while PG had the lowest and MM the highest percentage of voxels outside PItoh.
Artifacts observed in QSM at 9.4T with MM were mitigated by stronger background filters but yielded a reduced QSM contrast. With PB, QSM contrast was greater and artifacts diminished. Similar results were obtained with challenge data, evidencing larger effects of mask close to air cavities.
Conclusion
Automatic, phase‐based masking founded on the second derivative of the sign of the wrapped phase, including cortical voxels at the brain surface, was able to mitigate artifacts and restore QSM contrast across cortical and subcortical brain regions. |
---|---|
Bibliography: | Funding information FP7 Health, Grant/Award Number: EU‐LACH 16/T01‐0118; H2020 European Research Council, Grant/Award Number: Advanced Grant 834940; Horizon 2020, European Union, Austrian Science Fund, Grant/Award Number: 31452 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ISSN: | 0740-3194 1522-2594 1522-2594 |