Reference data for BabyBody‐plethysmographic measurements in Chinese neonates and infants

ABSTRACT Background and objective Population‐specific pulmonary function reference data are essential to identify the nature and severity of respiratory diseases. However, there is a lack of reference data for Chinese neonates and infants. The objective of this study was to develop reference data fo...

Full description

Saved in:
Bibliographic Details
Published inRespirology (Carlton, Vic.) Vol. 22; no. 8; pp. 1622 - 1629
Main Authors Jiang, Gaoli, Li, Albert, Wang, Libo, Qian, Liling, Cao, Yun, Huang, Jianfeng, Wan, Chengzhou, Zhang, Xiaobo
Format Journal Article
LanguageEnglish
Published Chichester, UK John Wiley & Sons, Ltd 01.11.2017
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:ABSTRACT Background and objective Population‐specific pulmonary function reference data are essential to identify the nature and severity of respiratory diseases. However, there is a lack of reference data for Chinese neonates and infants. The objective of this study was to develop reference data for tidal breathing and plethysmographic measurements for Chinese subjects during the first 2 years of life. Methods Data of tidal breathing and plethysmography from healthy Chinese neonates (≤28 days) and infants (1–24 months) using the Jaeger MasterScreen BabyBody were collated. All subjects were sedated for the tests. Multivariable analyses were performed to determine predictive variables for the pulmonary function parameters. Reference equations for outcomes were constructed using multilevel modelling and the LMS (lambda–mu–sigma) method was used for establishing smoothed reference percentiles. Results Four hundred and ten healthy subjects were tested. Acceptable measurements of tidal breathing analysis and plethysmography outcomes were obtained in 396 (96.6%) and 370 (90.4%) subjects, respectively. Normal reference percentiles and equations for the main parameters of tidal breathing and plethysmography were derived from test occasions of 211 neonates and 185 infants. Body weight, crown–heel length and age were significantly associated with lung function, of which length was the strongest predictor. Conclusion This study provides reference data of BabyBody‐plethysmographic measurements for healthy Chinese subjects in their first 2 years of life. Weight and length are the strongest predictors for neonatal and infant lung function, respectively. This is the first description of pulmonary function in healthy Chinese neonates and infants. Pulmonary function in Chinese differs to those of European descent and therefore population‐appropriate reference data are important.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1323-7799
1440-1843
DOI:10.1111/resp.13104