In vivo macromolecule signals in rat brain 1H‐MR spectra at 9.4T: Parametrization, spline baseline estimation, and T2 relaxation times

Purpose Reliable detection and fitting of macromolecules (MM) are crucial for accurate quantification of brain short‐echo time (TE) 1H‐MR spectra. An experimentally acquired single MM spectrum is commonly used. Higher spectral resolution at ultra‐high field (UHF) led to increased interest in using a...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 86; no. 5; pp. 2384 - 2401
Main Authors Simicic, Dunja, Rackayova, Veronika, Xin, Lijing, Tkáč, Ivan, Borbath, Tamas, Starcuk, Zenon, Starcukova, Jana, Lanz, Bernard, Cudalbu, Cristina
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc 01.11.2021
John Wiley and Sons Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose Reliable detection and fitting of macromolecules (MM) are crucial for accurate quantification of brain short‐echo time (TE) 1H‐MR spectra. An experimentally acquired single MM spectrum is commonly used. Higher spectral resolution at ultra‐high field (UHF) led to increased interest in using a parametrized MM spectrum together with flexible spline baselines to address unpredicted spectroscopic components. Herein, we aimed to: (1) implement an advanced methodological approach for post‐processing, fitting, and parametrization of 9.4T rat brain MM spectra; (2) assess the concomitant impact of the LCModel baseline and MM model (ie, single vs parametrized); and (3) estimate the apparent T2 relaxation times for seven MM components. Methods A single inversion recovery sequence combined with advanced AMARES prior knowledge was used to eliminate the metabolite residuals, fit, and parametrize 10 MM components directly from 9.4T rat brain in vivo 1H‐MR spectra at different TEs. Monte Carlo simulations were also used to assess the concomitant influence of parametrized MM and DKNTMN parameter in LCModel. Results A very stiff baseline (DKNTMN ≥ 1 ppm) in combination with a single MM spectrum led to deviations in metabolite concentrations. For some metabolites the parametrized MM showed deviations from the ground truth for all DKNTMN values. Adding prior knowledge on parametrized MM improved MM and metabolite quantification. The apparent T2 ranged between 12 and 24 ms for seven MM peaks. Conclusion Moderate flexibility in the spline baseline was required for reliable quantification of real/experimental spectra based on in vivo and Monte Carlo data. Prior knowledge on parametrized MM improved MM and metabolite quantification.
Bibliography:Correction added after online publication 10 August 2021. The authors have corrected the images for Figures 3 and 4 which were swapped in the prior version.
ISSN:0740-3194
1522-2594
DOI:10.1002/mrm.28910