Screening for chronic cerebrospinal venous insufficiency (CCSVI) using ultrasound - Recommendations for a protocol

Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome characterized by stenoses or obstructions of the internal jugular and/or azygos veins with disturbed flow and formation of collateral venous channels. Studies using ultrasound in patients with multiple sclerosis (MS) have demonstrated...

Full description

Saved in:
Bibliographic Details
Published inInternational angiology Vol. 30; no. 6; pp. 571 - 597
Main Authors ZAMBONI, P, MOROVIC, S, MENEGATTI, E, VISELNER, G, NICOLAIDES, A. N
Format Journal Article Conference Proceeding
LanguageEnglish
Published Torino Minerva Medica 01.12.2011
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome characterized by stenoses or obstructions of the internal jugular and/or azygos veins with disturbed flow and formation of collateral venous channels. Studies using ultrasound in patients with multiple sclerosis (MS) have demonstrated a high prevalence of CCSVI (mean 70%; range 0-100%; N.=1496), whereas, in normal controls and patients without MS the prevalence was much lower (mean 10%; range 0-36%; N.=635). Ultrasound uses a combination of physiological measurements as well as anatomical imaging and has been used for the detection of CCSVI by different centers with variable results. A high prevalence ranging from 62% to 100% of obstructive lesions has been found by some teams in patients with MS compared with a lower prevalence of 0-25% in controls. However, absence of such lesions or a lower prevalence (16-52%) has been reported by others. This variability could be the result of differences in technique, training, experience or criteria used. The current lack of a methodology shared among experts is a confounding element in epidemiologic studies, and does not permit further Bayesan or other kind of analysis. In order to ensure a high reproducibility of Duplex scanning with comparable accuracy between centers, a detailed protocol with standard methodology and criteria is proposed. This is also necessary for training. It has been shown that inter-rater variability increases post-training (from k=0.47 to k=0.80), while within-rater reproducibility in trained operators was k=0.75. Finally, the consensus document proposes a reporting standard of Duplex measurements, and future research to answer areas of uncertainty.
Bibliography:ObjectType-Article-1
ObjectType-News-3
ObjectType-Instructional Material/Guideline-2
SourceType-Conference Papers & Proceedings-1
ObjectType-Conference-4
ObjectType-Feature-5
content type line 25
ISSN:0392-9590
1827-1839