Advancements in the Mo.Ma system procedure during carotid artery stenting

The aim of this paper was to reduce the incidence of clamping intolerance, asystolia, immediate mortality and neurological complications associated with carotid artery stenting (CAS) using the Mo.Ma system (Invatec, Roncadelle Brescia, Italy) embolic protection device (EPD). CAS was perfomed using t...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiovascular surgery Vol. 50; no. 6; pp. 789 - 793
Main Authors Coppi, G, Moratto, R, Silingardi, R, Veronesi, J, Nicolosi, E, Chester, J
Format Journal Article
LanguageEnglish
Published Italy Edizioni Minerva Medica 01.12.2009
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The aim of this paper was to reduce the incidence of clamping intolerance, asystolia, immediate mortality and neurological complications associated with carotid artery stenting (CAS) using the Mo.Ma system (Invatec, Roncadelle Brescia, Italy) embolic protection device (EPD). CAS was perfomed using the Mo.Ma system in 312 patients between January 2002-October 2009. From October 2008 variations to the standard technique were introduced. A total of 214 patients were treated with the standard technique, and 88 with the new technique. Improvements include the engagement of the guidewire's floppy tip through the lesion whilst the cerebral blood flow is maintained, a slow release post-dilation (1 atm/2 s), a quicker manual aspiration procedure following post-dilation, a redirection of blood flow into the external carotid artery (ECA) with the post-dilation balloon inflated in the internal carotid artery (ICA), and a further manual aspiration and the subsequent release of the Mo.Ma system. This study reports reduced incidence of clamping intolerance (7.9% vs. 4.5%), asystolia (0 vs. 1.9%), immediate mortality (0 vs. 0.9%) and neurological complications (1.1% vs. 3.7%). The only neurological complication associated with the new technique was a transient ischemic attack (TIA). The new variations of the standard Mo.Ma technique seem rational in the improvement of the safety and efficacy of CAS using an EPD, in reducing the incidence of clamping intolerance and asystolia, immediate mortality and neurological complications. This series indicates a positive trend for this revised technique, but a multicentre registry is required to validate these promising results.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0021-9509
1827-191X