Transcatheter aortic valve replacement for aortic bioprosthetic valve failure with cardiogenic shock

Acutely failing bioprosthetic valves represent a clinical emergency and are exceedingly challenging given the paucity of therapeutic options. Oftentimes, these patients are not re-operative candidates due to clinical instability. We present 2 cases of acute degenerative aortic bioprosthetic valve fa...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of invasive cardiology Vol. 25; no. 11; pp. 625 - 626
Main Authors Fudim, Marat, Markley, Roshanak R, Robbins, Mark A
Format Journal Article
LanguageEnglish
Published United States 01.11.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Acutely failing bioprosthetic valves represent a clinical emergency and are exceedingly challenging given the paucity of therapeutic options. Oftentimes, these patients are not re-operative candidates due to clinical instability. We present 2 cases of acute degenerative aortic bioprosthetic valve failure with cardiogenic shock treated with transcatheter aortic valve replacement (TAVR). These cases were characterized by hemodynamic instability with vasopressor dependence and (multiple) organ failure. These 2 cases demonstrate that TAVR should be considered as a treatment option for unstable patients with bioprosthetic failure.
Bibliography:ObjectType-Case Study-2
SourceType-Scholarly Journals-1
ObjectType-Feature-4
content type line 23
ObjectType-Report-1
ObjectType-Article-3
ISSN:1557-2501