Implications of initiating antiseizure drugs prior to the performance of EEG in first epileptic seizures
This study aimed to determine whether the administration of antiepileptic drugs (AED) alters the likelihood of detecting epileptiform abnormalities in electroencephalographies (EEG) performed early after a first epileptic seizure. We performed a retrospective, observational study including patients...
Saved in:
Published in | Neurología (Barcelona, English ed. ) |
---|---|
Main Authors | , , , , , , , , , , |
Format | Journal Article |
Language | English Spanish |
Published |
Spain
01.11.2023
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | This study aimed to determine whether the administration of antiepileptic drugs (AED) alters the likelihood of detecting epileptiform abnormalities in electroencephalographies (EEG) performed early after a first epileptic seizure.
We performed a retrospective, observational study including patients with a first seizure attended at our centre's emergency department between July 2014 and November 2019. We collected clinical data, as well as technical data on the acquisition and interpretation of the EEG performed within the first 72hours after the seizure, and the factors related with seizure recurrence.
We recruited 155 patients with a mean (SD) age of 48.6 (22.5) years; 61.3% were men. Regarding seizure type, 51% presented tonic-clonic seizures of unknown onset and 12% presented focal to bilateral tonic-clonic seizures. Thirty-nine patients (25.2%) received AED treatment before the EEG was performed: 33 received a non-benzodiazepine AED and 6 received a benzodiazepine. Epileptiform abnormalities were observed in 29.7% of patients. Previous administration of AEDs was not significantly associated with the probability of detecting interictal epileptiform abnormalities (P=.25) or with the risk of recurrence within 6 months (P=.63).
Administration of AEDs before an early EEG following a first seizure does not decrease the likelihood of detecting epileptiform abnormalities. These findings suggest that starting AED treatment immediately in patients with a high risk of early recurrence does not imply a reduction in the diagnostic accuracy of the test. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 2173-5808 |
DOI: | 10.1016/j.nrl.2021.02.014 |