Ventricular Synchrony in Para-Hisian Cardiac Pacing as an Alternative for Physiological Cardiac Activation (Indirect Recruitment of the His Bundle?)

Artificial cardiac pacing by direct or indirect His bundle capture results in synchronous ventricular contraction (physiological pacing). To compare cardiac synchronization, technical characteristics, and electronic parameters between two techniques of indirect His-bundle pacing: non-selective (NS-H...

Full description

Saved in:
Bibliographic Details
Published inArquivos brasileiros de cardiologia Vol. 118; no. 2; pp. 488 - 502
Main Authors Ferrari, Andres Di Leoni, Gazzoni, Guilherme Ferreira, Domingues, Luis Manuel Ley, Willes, Jessica Caroline Feltrin, Cabral, Gustavo Chiari, Ferreira, Flavio Vinicius Costa, Lodi, Laura Orlandini, Reis, Gustavo
Format Journal Article
LanguageEnglish
Published Brazil 01.02.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Artificial cardiac pacing by direct or indirect His bundle capture results in synchronous ventricular contraction (physiological pacing). To compare cardiac synchronization, technical characteristics, and electronic parameters between two techniques of indirect His-bundle pacing: non-selective (NS-HBP) vs para-Hisian pacing (PHP). The experimental intervention (between November 2019 and April 2020) consisted of implanting a DDD pacemaker in patients who had left ventricular ejection fraction (LVEF) > 35%. The resulting cardiac synchronization was compared using an electrocardiographic algorithm that analyzed QRS variation and the technical characteristics of non-selective Hisian pacing (DDD-His) and para-Hisian pacing (DDD-Var). Of 51 total patients (men: 28), 66.7% (34) were allocated to the DDD-Var group and 33.3% (17) to the DDD-His group. The mean ages in each group were 74 and 79 years, respectively. In the DDD-Var group, QRS variation (ventricular synchrony) improved after implantation (p < 0.001). In post-implantation ECG, 91.2% of the DDD-Var group presented a physiological pacing pattern, which was similar to the DDD-His group (88.2%; p = 0.999). The paced QRS axis was also similar (physiological) for both groups. Intraoperative fluoroscopy time (XRay) during implantation was lower for the para-Hisian technique (median 7 min in the DDD-Var group vs 21 min in the DDD-His group, p < 0.001). The mean QRS duration increased in the DDD-Var group (114.7 ms pre-implantation vs 128.2 ms post-implantation, p = 0.044). The mean post-implantation R-wave amplitude was 11.2 mV in the DDD-Var group vs 6.0 mV in the DDD-His group, p = 0.001. Para-Hisian pacing appears to indirectly recruit the His bundle, which would make this an effective and comparable strategy for physiological pacing, resulting in synchronous ventricular contraction similar to that of non-selective Hisian pacing.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1678-4170
DOI:10.36660/abc.20201233