Clinical outcome of double valve repalcement with or without small aortic prosthesis

To determine the effect of aortic prosthesis size on clinical outcome of patients undergoing double cardiac valve replacement (DVR). A quasi-experimental study. Cardiac Surgery Department, Punjab Institute of Cardiology, Lahore, Pakistan, from February 1996 to December 2008. One hundred and forty pa...

Full description

Saved in:
Bibliographic Details
Published inJournal of the College of Physicians and Surgeons--Pakistan Vol. 22; no. 10; pp. 617 - 621
Main Authors Akhtar, Raja Parvez, Abid, Abdul Rehman, Nuqshband, Mumraiz Salik, Khan, Jawad Sajid
Format Journal Article
LanguageEnglish
Published Pakistan 01.10.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To determine the effect of aortic prosthesis size on clinical outcome of patients undergoing double cardiac valve replacement (DVR). A quasi-experimental study. Cardiac Surgery Department, Punjab Institute of Cardiology, Lahore, Pakistan, from February 1996 to December 2008. One hundred and forty patients undergoing double cardiac valve replacement were divided into 2 groups. Group I, 75 (53.6%) receiving aortic prosthesis size of ² 21 mm. Group II, 65 (46.4%) having aortic prosthesis of > 21 mm size. All patients were prospectively followed-up for 12 years in order to study mortality and valve related complications. There were 94 males (67.1%) and 46 females (32.9%) with a mean age of 25.5 ± 10 years. In Group I, 21 patients (28%) had aortic valve replacement (AVR) with 19 mm valve size and 54 patients (72%) had 21 mm size valves implanted. In Group II, 39 patients (60%) had AVR with 23 mm size valves implanted followed by 16 (24.6%) who received 25 mm size valves. Posterior mitral leaflet was preserved in 15 patients (20%) in Group I and 14 (21.5%) in Group II. Mortality was seen in 13 patients (9.3%); of these 5 (3.6%) were in Group I and 8 (5.7%) were in Group II. Nine patients (6.4%) had incomplete follow-up (In Group I, 2 patients died in ICU, 2 died within 30 days of admission and one was a late death. In Group II, 1 patient died in ICU, 1 within 30 days of admission and 6 within 1 year of operation). Double valve replacement with implantation of small aortic prosthesis has similar overall mortality as compared to patients having larger sized aortic valves.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1681-7168
DOI:10.2012/JCPSP.617621