Ventilator setting in ICUs: comparing a Dutch with a European cohort

From data collected during the third International Study on Mechanical Ventilation (ISMV), we compared data from a Dutch cohort with a European cohort. We hypothesised that tidal volumes were smaller and applied positive end-expiratory pressure (PEEP) was higher in the Netherlands, compared with the...

Full description

Saved in:
Bibliographic Details
Published inNetherlands journal of medicine Vol. 72; no. 9; pp. 473 - 480
Main Authors van IJzendoorn, M C O, Koopmans, M, Strauch, U, Heines, S, den Boer, S, Kors, B M, van der Voort, P H J, Dennesen, P J W, van den Hul, I, Alberts, E, Egbers, P, Esteban, A, Frutos-Vivar, F, Kuiper, M A
Format Journal Article
LanguageEnglish
Published Netherlands 01.11.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:From data collected during the third International Study on Mechanical Ventilation (ISMV), we compared data from a Dutch cohort with a European cohort. We hypothesised that tidal volumes were smaller and applied positive end-expiratory pressure (PEEP) was higher in the Netherlands, compared with the European cohort. We also compared use of non-invasive ventilation (NIV) and outcomes in both cohorts. A post-hoc analysis of a prospective observational study of patients receiving mechanical ventilation. Tidal volumes were smaller (7.6 vs. 8.1 ml÷kg predicted bodyweight) in the Dutch cohort and applied PEEP was higher (8 vs. 6 cm H2O). Fewer patients admitted in the Netherlands received NIV as first mode of mechanical ventilation (7.1 vs. 16.7%). Fewer patients in the Dutch cohort developed an ICU-acquired pneumonia (4.5 vs. 12.3%, p < 0.01) and sepsis (5.7 vs. 10.9%, p = 0.03), but more patients were diagnosed as having delirium (15.8 vs. 4.6%, p < 0.01). ICU and in-hospital mortality rates were 19% and 25%, respectively, in Dutch ICUs vs. 26% and 33% in Europe (p = 0.06 and 0.03). Tidal volumes were smaller and applied PEEP was higher in the Dutch cohort compared with international data, but both Dutch and international patients received larger tidal volumes than recommended for prevention or treatment of acute respiratory distress syndrome. NIV as first mode of mechanical ventilation is less commonly used in the Netherlands. The incidence of ICU-acquired pneumonia is lower and of delirium higher in the Netherlands compared with international data.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:1872-9061