Diagnostic usefulness of postexercise systolic blood pressure response for detection of coronary artery disease in patients with echocardiographic left ventricular hypertrophy
Although exercise-induced electrocardiographic ST segment changes are used to detect coronary artery disease (CAD), their diagnostic value is markedly decreased in patients with left ventricular (LV) hypertrophy. There have been no reports concerning postexercise systolic blood pressure (SBP) respon...
Saved in:
Published in | Canadian journal of cardiology Vol. 20; no. 7; p. 705 |
---|---|
Main Authors | , , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
England
15.05.2004
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Summary: | Although exercise-induced electrocardiographic ST segment changes are used to detect coronary artery disease (CAD), their diagnostic value is markedly decreased in patients with left ventricular (LV) hypertrophy. There have been no reports concerning postexercise systolic blood pressure (SBP) response in patients with ultrasound echocardiographic (UCG) LV hypertrophy and CAD.
Sixty-six patients with both UCG-LV hypertrophy (LV mass index 134 g/m2 or greater for men or 110 g/m2 or greater for women) and positive ST depression of at least 0.1 mV during treadmill exercise testing were studied. Coronary cineangiograms showed normal coronary arteries in 19 patients (group 1) and significant CAD in 47 patients (group 2). The SBP ratio was calculated by dividing the SBP 3 min after exercise (3 min SBP) by the SBP at peak exercise (peak SBP).
There were no significant differences between the two groups in LV mass index, SBP at rest, exercise duration, ST depression (at rest and exercise-induced) or 3 min SBP. However, the SBP ratio was significantly higher in group 2 compared with group 1 (0.87+/-0.11 versus 1.01+/-0.18; P=0.004). Analysis of relative cumulative frequency distributions revealed an SBP ratio of 0.92 as the cutoff point for distinguishing a UCG-LV hypertrophy patient with CAD from one without CAD. The sensitivity, specificity and accuracy with an SBP ratio of 0.92 and an ST segment depression of at least 0.1 mV on treadmill exercise testing for detecting CAD in patients with UCG-LV hypertrophy were 77%, 74% and 76%, respectively.
These findings suggest that the ratio of early post-exercise SBP to peak exercise SBP may be diagnostically useful in detecting CAD in patients with positive ST depression during an exercise test and UCG-LV hypertrophy. |
---|---|
ISSN: | 0828-282X |