Imaging sequence for joint myocardial T1 mapping and fat/water separation

Purpose To develop and evaluate an imaging sequence to simultaneously quantify the epicardial fat volume and myocardial T1 relaxation time. Methods We introduced a novel simultaneous myocardial T1 mapping and fat/water separation sequence (joint T1‐fat/water separation). Dixon reconstruction is perf...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 81; no. 1; pp. 486 - 494
Main Authors Nezafat, Maryam, Nakamori, Shiro, Basha, Tamer A., Fahmy, Ahmed S., Hauser, Thomas, Botnar, René M.
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc 01.01.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To develop and evaluate an imaging sequence to simultaneously quantify the epicardial fat volume and myocardial T1 relaxation time. Methods We introduced a novel simultaneous myocardial T1 mapping and fat/water separation sequence (joint T1‐fat/water separation). Dixon reconstruction is performed on a dual‐echo data set to generate water/fat images. T1 maps are computed using the water images, whereas the epicardial fat volume is calculated from the fat images. A phantom experiment using vials with different T1/T2 values and a bottle of oil was performed. Additional phantom experiment using vials of mixed fat/water was performed to show the potential of this sequence to mitigate the effect of intravoxel fat on estimated T1 maps. In vivo evaluation was performed in 17 subjects. Epicardial fat volume, native myocardial T1 measurements and precision were compared among slice‐interleaved T1 mapping, Dixon, and the proposed sequence. Results In the first phantom, the proposed sequence separated oil from water vials and there were no differences in T1 of the fat‐free vials (P = .1). In the second phantom, the T1 error decreased from 22%, 36%, 57%, and 73% to 8%, 9%, 16%, and 26%, respectively. In vivo there was no difference between myocardial T1 values (1067 ± 17 ms versus 1077 ± 24 ms, P = .6). The epicardial fat volume was similar for both sequences (54.3 ± 33 cm3 versus 52.4 ± 32 cm3, P = .8). Conclusion The proposed sequence provides simultaneous quantification of native myocardial T1 and epicardial fat volume. This will eliminate the need for an additional sequence in the cardiac imaging protocol if both measurements are clinically indicated.
Bibliography:Funding information
The British Heart Foundation (RG/12/1/29262), the Center of Excellence in Medical Engineering funded by the Wellcome Trust and EPSRC (WT 088641/Z/09/Z), the EPSRC (EP/P001009/1 and EP/P007619/1), FONDECYT No. 1161051 and CONICYT‐ANILLO ACT 1416, and the Department of Health through the National Institute for Health Research comprehensive Biomedical Research Center award to Guy's & St. Thomas' NHS Foundation Trust in partnership with King's College London and King's College Hospital NHS Foundation Trust and National Institutes of Health (R01‐HL12915701)
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0740-3194
1522-2594